W-2532: Difference between revisions

From Color Services Wiki
Jump to navigation Jump to search
Line 6: Line 6:
#A window will open up. Type the password ''7777'' and click enter. This will let you enter the application as an administrator.
#A window will open up. Type the password ''7777'' and click enter. This will let you enter the application as an administrator.
#Click on '''5-Printer Adjustment/Maintenance'''.
#Click on '''5-Printer Adjustment/Maintenance'''.
#Then click on item '''[454] G Laser(SHG) Optimal Temperature Setup'''.
#Then click on item '''[454] - G Laser(SHG) Optimal Temperature Setup'''.
#Click '''Enter'''. This will cause the system to perform the ''laser optimal temperature adjustment''. The process will take about 5 minutes.
#Click '''Enter'''. This will cause the system to perform the ''laser optimal temperature adjustment''. The process will take about 5 minutes.
#Once the process it finished the '''Measured value''' should read ''OK''.
#Once the process it finished the '''Measured value''' should read ''OK''.
#Click '''Close'''. This will take you back to the '''admin-Panda''' and you'll be ready to start printing.
#Click '''Close'''. This will take you back to the '''admin-Panda''' and you'll be ready to start printing.

Revision as of 16:15, 15 March 2013

This is an error code that comes up periodically on the Frontier 570.
Warning W-2532
G laser (G-SHG) optimal temperature setting periods.
Press [Help] button to see error help (or manual). Set optimal temperature for G laser (G-SHG) while referring to it.

Course of Action

  1. In the admin-Panda application on the 570 computer, click on 4-Maintenance on the lower part of the application window.
  2. A window will open up. Type the password 7777 and click enter. This will let you enter the application as an administrator.
  3. Click on 5-Printer Adjustment/Maintenance.
  4. Then click on item [454] - G Laser(SHG) Optimal Temperature Setup.
  5. Click Enter. This will cause the system to perform the laser optimal temperature adjustment. The process will take about 5 minutes.
  6. Once the process it finished the Measured value should read OK.
  7. Click Close. This will take you back to the admin-Panda and you'll be ready to start printing.